Overview

Unified Alerts brings all of your alert configuration into one place. You can create alert rules for devices and collectors, choose how severe each alert is, send notifications to email, mobile, messaging apps, webhooks or your PSA/ticketing system, and review every alert that has fired, without leaving Domotz.

How Unified Alerts works

Unified Alerts is built on a few simple ideas:

  • Alert rule: A rule defines what to watch and when to alert, for example “Device Status went down” or “Disk Usage is greater than 90%”. It also sets the severity and the contact channels/notification channels to notify.
  • Applying a rule: A rule does nothing on its own. It only starts monitoring once you apply it to one or more devices or collectors. You can apply the same rule to as many devices or collectors as you like.
  • Alert: When an applied rule’s condition is met, Domotz opens an alert, sends notifications, and records the alert in Alert Activity.
  • Auto-resolve: If the condition can clear (for example, a value drops back below its threshold, or a device that went down comes back online), Domotz resolves the alert automatically. You only need to resolve alerts manually when there is no condition that can clear.

In short: create the rule once, then apply it wherever you need it.

Where to find alerts

Navigate to Alerts in the left sidebar. The Alerts page has these tabs:

  • Alert Activity: every alert triggered for your account, open and resolved.
  • Alert Rules: the Alert Rules Inventory, a list of every alert rule in your account.
  • Maintenance Windows: scheduled periods when monitoring or notifications are paused for chosen collectors or devices.
  • Contact Channels & Ticketing Systems: where you set up the email addresses, push notification recipients, messaging services, webhooks and ticketing systems that receive alerts.
Alerts page showing the Alert Activity, Alert Rules, Maintenance Windows and Contact Channels & Ticketing Systems tabs, with the Critical, High and Warning counters in the left sidebar

Under Alerts in the left sidebar you will also see live counters for open Critical, High and Warning alerts. Click a counter to jump straight to those alerts.

You can also manage alerts for a specific collector or device:

  • Collector: open the collector and select the Alerts tab.
  • Device: open the device and select the Alerts tab.

Severity levels

Each alert rule can have one of these severity levels:

  • Critical
  • High
  • Warning
  • Info
  • No Severity
Severity dropdown showing Critical, High, Warning, Info and No Severity

Severity is shown on every alert and can be used to filter Alert Activity. If you change a rule’s severity, the change applies everywhere that rule is applied.

Set up contact channels/notification channels

Contact channels/notification channels are the destinations Domotz notifies when an alert fires. Set these up first so they are ready to select when you create alert rules.

  1. Navigate to Alerts in the left sidebar and select the Contact Channels & Ticketing Systems tab. The Contact Channels Configuration page opens.
  2. Add the channels you need:
    • Emails: click Add Email and enter any email address. It does not need to belong to a Domotz user.
    • Push Notifications: users on your account, listed as Team Leader and Team Members, can receive alerts as mobile push notifications through the Domotz app.
    • Ticketing Systems: click Connect Account next to your PSA or ticketing system. Supported systems include Autotask PSA, ConnectWise PSA, Kaseya BMS, RepairShopr, ServiceNow, Syncro, FreshService, FreshDesk, Q360, Zendesk and HaloPSA.
    • Messaging Services: click Add Webhook next to Slack, Microsoft Teams or Telegram and paste the webhook URL from that service.
    • Webhooks: click Add Webhook to send alerts to any third-party endpoint.
  3. Use the test icon next to a channel to send a test message and confirm it is working.
Contact Channels Configuration page showing configured emails, webhooks and push notifications, and the Ticketing Systems list

Note: You can also add channels while creating an alert rule. In the channel picker, click Need to configure more Notification Channels? to jump to this page.

Create an alert rule

Once your contact channels/notification channels are ready, create the alert rules you need.

  1. Navigate to Alerts in the left sidebar and select the Alert Rules tab.
  2. Click Add Alert Rule. The Alert Rule Details panel opens.
  3. Enter an Alert Name.
  4. Under Target, choose:
    • Entity: Collector or Device.
    • Datapoint: the metric or event to watch. Datapoints are grouped into categories, and you can search for one by name.
      • Collector categories include Connectivity, Internet Performance, Monitoring Service Health, Network Activity, Network Configuration and Security.
      • Device categories include Connectivity, Monitoring Service Health, Scripts, SNMP Sensors and TCP Sensors.
Datapoint picker, "Select a Datapoint to define an Alert", showing the categories
  1. Under Trigger Definition, choose:
    • Condition: when the alert should fire. For event datapoints, choose the event, such as Is Down or New Device Discovered. In the Alert Rules list, these appear in plain language, such as “went down” or “discovered”. For numeric datapoints you can choose Is Equal To, Is Greater Than, Is Greater Than Or Equal To, Is Less Than, Is Less Than Or Equal To, Is In A Range Between, Is Different From or Has Changed, and then enter a Value.
    • Severity: Critical, High, Warning, Info or No Severity.
  2. Under Notification Channels, click Add Channels, select the channels to notify, and click Set Channels. You can skip this step and add channels later.
  3. Click Save.
Completed Alert Rule Details panel with Alert Name, Target, Trigger Definition and Notification Channels filled in

Important: A rule created on the Alert Rules tab is not active on anything yet. Apply it to devices or collectors as described in the next section.

Note: The Entity and Datapoint cannot be changed after a rule is created, and clones keep the same Entity and Datapoint. To watch a different datapoint, create a new rule and delete the old one if you no longer need it.

Managing existing rules

The Alert Rules Inventory lists every rule with its name, datapoint, condition, severity, notification channels, entity type, what it is applied to, and when it was created.

Alert Rules Inventory showing the rule list, Status toggles and Send Test links
  • Search and filter: use the search box or the filter at the top of each column. Use Manage Columns to show or hide columns.
  • Enable or disable: use the Status toggle to turn a rule on or off without deleting it.
  • Send a test: click Send Test to send a sample alert to the rule’s contact channels/notification channels.
  • Edit, clone or delete: click a rule to open its details. You can change the name, condition, severity and channels, then click Save. Use Clone to make a copy or Delete to remove it. If the rule is already applied, a banner at the top of the panel shows how many devices or collectors use it. Your changes apply to all of them.
  • Bulk actions: select several rules with the checkboxes to update or delete them together.
Editing an existing rule, showing the Applied to banner, the Enable Alert Rule toggle, the locked Entity and Datapoint fields, and the Save, Send Test, Clone and Delete buttons

Apply alert rules

After you create a rule, apply it to the devices or collectors you want to monitor. You can do this in several ways. Whichever method you use, you will see a list of compatible rules with checkboxes. Ticking a rule applies it immediately, and unticking removes it. There is no separate save step. Each rule shows how many devices or collectors it is linked to. Each list also has a Configure new Alert option to create a new rule on the spot.

Apply rules to a single device

  1. Open a collector, select the Devices tab, and click a device.
  2. Select the Alerts tab.
  3. Datapoints are grouped by category, such as Connectivity (Device Status, Heartbeat Lost, IP Address, Ping RTD Median Latency, Ping RTD Packet Loss), SNMP Sensors, TCP Ports and Monitoring Service Health. Rules already applied are shown next to each datapoint with their severity. Use the All / With Alerts / Without Alerts filters to see what is already covered.
  4. Click + next to a datapoint.
  5. Tick an existing rule, or click Configure new Alert, fill in the details, and click Save and Apply.
Device Alerts tab showing the Connectivity datapoints with their applied rules and severities

Apply a rule to a specific sensor value

You can set an alert directly from a value on a device’s Drivers, SNMP or TCP tab. This is useful for alerting on one specific item, such as a single disk or interface.

  1. Open the device and select the Drivers, SNMP or TCP tab.
  2. Hover over the value you want to monitor and click the alert (bell) icon next to it.
  3. In the Alert Rules List, tick an existing rule, or click Configure new Alert, set the condition, value and severity, and click Save and Apply.
Drivers tab showing the Set an Alert (bell) icon next to a disk's Usage value

Note: A rule applied this way only covers that single instance. For example, setting an alert on the Usage of drive C does not alert on the device’s other drives.

Apply rules to a collector

  1. Open the collector and select the Alerts tab.
  2. Choose Network or Devices.
  3. Find the datapoint you want, using search or the All / With Alerts / Without Alerts filters, and apply or edit the rule. Rules already applied are shown next to each datapoint with their severity.
Collector Alerts tab (Network view) showing the categories, with the Collector Status rule applied

Apply rules in bulk

To apply rules to many devices or collectors at once:

  • Devices on one collector: on the collector’s Devices tab, select the devices, then in the Edit Device details panel click the edit icon next to Alert Rules.
  • Devices across collectors: navigate to Inventory in the left sidebar and select the Devices tab. Select the devices, then click the edit icon next to Alert Rules in the Edit Device details panel.
  • Collectors: navigate to Inventory in the left sidebar and select the Collectors tab. Select the collectors, and open the Alert Rules list (or click Manage in the Alert Rules column).

Tick the rules to apply them to every selected device or collector.

Inventory Devices tab with three devices selected and the edit icon next to Alert Rules in the Edit Device details panel

Apply alert rules automatically with Device Profiles

Device Profiles apply a set of configurations, including alert rules, to every device that matches a filter. Because profile filters are dynamic, a scheduled profile also picks up new devices that match the filter, so new devices get your alert rules automatically.

Note: Device Profiles apply device alert rules only. Collector alert rules are applied from the collector or from Inventory.

Create a profile with alert rules

  1. Navigate to Profiles in the left sidebar and click Add Profile.
  2. Enter a Profile Name and click Create. The Profile details panel opens.
  3. Next to Device Filter, click the edit icon and select a saved filter, or click Create a new Custom Filter (for example, Device Type is Router, Switch or Firewall). Click Save Filter as Default.
  4. (Optional) Next to Schedule, click Add schedule, choose Hourly, Daily or Weekly and a time, and click Confirm & Activate. The schedule re-applies the profile automatically, including to newly matching devices.
  5. Under Configuration, select the Alerts tab and turn on Include the Alerts Module in the Profile.
  6. Choose an Application method:
    • Add to Device’s Alerts configuration: adds the profile’s rules and keeps any rules already applied to the device.
    • Overwrite Device’s Alerts configuration: replaces all of the device’s existing alert rules with only the rules in this profile.
  7. Tick the alert rules to include.
Profile details panel on the Alerts tab, showing the Include the Alerts Module toggle, the Application method dropdown and the selected rules

Apply the profile

  1. Click Apply.
  2. Choose which devices to apply it to:
    • Static Selection: only the devices you explicitly select.
    • Select using a Saved Filter: all devices that match the filter.
  3. Click Apply Profile.
  4. Review the confirmation, tick the acknowledgement box, and click Continue.
The "Applying a Profile cannot be undone" confirmation dialog, with the acknowledgement checkbox and the Cancel and Continue buttons

Important: Applying a profile cannot be undone. Deleting a profile does not remove the rules it applied. To reverse a profile, remove the rules from the devices manually, or apply another profile using Overwrite Device’s Alerts configuration.

Review and resolve alerts in Alert Activity

Navigate to Alerts in the left sidebar and select the Alert Activity tab to see every alert triggered for your account.

  • Date Range: choose the period to show (for example, Last 1 week) with the selector at the top left.
  • Counters: next to the date range, counters show the total number of alerts and how many are open, plus a count for each severity (Critical, High, Warning, Info and No Severity). Click a counter to filter the list by it.
  • Filters: the filters in use are listed under Filtered by. Click the x next to a filter to remove it. Click Save Custom Filter to reuse a set of filters, and pick it later from Select a Custom Filter.
  • Chart: shows the number of alerts over the selected period, stacked by severity.
  • Search: search by alert, trigger or Alert ID.
  • Columns:
    • What happened | Rule: what the alert is about (for example, “Front Desk PC went offline”), with the rule and the value that triggered it underneath (for example, “Device Status: Down”).
    • Where: the collector the alert relates to.
    • Location | Zone, When (when the alert triggered), Open for (whether the alert is open or resolved, and how long it was open), Resolved at, Tags, Importance (whether the device is marked Important) and Alert ID.
    • Each column has a filter or sort control under its heading. Use Manage Columns to show or hide columns.
Alert Activity page showing the counters, chart and alert list with open and resolved alerts

View alert details

Click an alert to open the Edit Alert Details panel. It has two tabs:

  • Metrics & Details:
    • The Alert Rule that fired (click it to open the rule), the Datapoint, the Identifier of the specific instance, the Condition and the Value that triggered the alert.
    • Status, Severity, ID, Triggered at, Duration, Resolved at, whether a Notification was sent, and who or what Resolved it.
    • For metric alerts, a Metric history chart and an Analysis of the metric (trend, baseline, change points and anomalies).
  • Infrastructure: the collector and device the alert relates to.
Edit Alert Details panel on the Metrics & Details tab, showing the edit icons next to Status and Severity

Resolve an alert or change its severity

Most alerts resolve themselves. When the condition clears, for example when a device comes back online or a value returns within its threshold, Domotz resolves the alert automatically. To resolve an alert manually, or to change its severity:

  1. Click the alert to open Edit Alert Details.
  2. Click the edit (pencil) icon next to Status and set it to Resolved, or click the edit icon next to Severity and choose a new level.

To update several alerts at once, select them with the checkboxes in the list and change their status or severity together.

Note: Severity can only be changed on open alerts.

Pause alerts with maintenance windows

Use a maintenance window to stop alerts while planned work is happening, for example firmware updates, scheduled reboots or ISP maintenance. A window can run once or on a schedule, and applies to the collectors or devices you choose.

Maintenance Windows list showing three windows: ISP Maintenance (Running), Nightly Backups (Scheduled) and Weekly Firmware Updates (Scheduled)

Choose how alerts are paused

Each window uses one of two suppression behaviors:

Suppression behaviorWhat happens during the window
Pause monitoringNo checks run, so no alerts are created or recorded.
Pause notifications onlyMonitoring continues and alerts are recorded in Alert Activity, but no notifications are sent.

With Pause monitoring, you can also select Alert on issues still open when the window ends. Anything still failing when the window ends is then alerted and notified as usual. Without this option, an issue that is still open when the window ends is not alerted. Domotz alerts again only on the next change, for example if the device comes back online and then goes down again.

Tip: Use Pause notifications only when you still want a record in Alert Activity of what happened during the work.

Create a maintenance window

  1. Navigate to Alerts in the left sidebar and select the Maintenance Windows tab.
  2. Click Add Maintenance Window.
  3. Enter a Window name.
  4. Expand Target and choose what the window applies to:
    • Collectors: the collector and all of its devices. Click Select Collectors to choose them.
    • Devices: only the devices you choose, not their collector. Click Select Devices to choose them.

When selecting, choose either:

  • Static selection: only the collectors or devices you select.
  • Dynamic selection: everything that matches a custom filter, including collectors or devices discovered later. Choose a filter from the list or click Create a new Custom Filter, then click Apply. Click Preview of n devices to see which devices the filter currently matches.
Select Devices screen with Dynamic selection chosen and the Networking Devices filter selected
  1. Expand Recurrence & duration and choose how often the window runs:
    • One shot: runs once, today. It starts either now or at a time you set later today, and you choose only how long it lasts.
    • Daily: runs every day.
    • Weekly: runs on the days you select under On (Mon to Sun).
    • Monthly: runs once a month, on the day of the month you select under Recurrence.

Set the Start time, then set how long the window lasts: choose a preset (1h, 2h, 3h, 4h, 6h or 12h), enter a number of hours, or click Precise time to set an exact end time.

Note: A one-shot window can’t be scheduled for a later date. To cover one-off work on a future day, create the window on the day of the work.

A window can run past midnight. For example, a daily window from 11:00 PM lasting 3h ends at 2:00 AM the next day.

Recurrence & duration set to Weekly on Sunday, starting at 2:00 AM for 2h
  1. Check the Timezone. It defaults to the collector’s time zone. The window runs in this time zone.
  2. Expand Suppression behavior and choose Pause monitoring or Pause notifications only (see the table above).
Suppression behavior expanded, with Pause monitoring and Alert on issues still open when the window ends selected
  1. Under End date, leave None for the window to repeat indefinitely, or choose On a date to stop it on a set date.
  2. Check the Summary at the bottom of the panel, then click Save Window.
Completed Weekly Firmware Updates window targeting the Networking Devices filter, with the Summary: Suppress all monitoring on the "Networking Devices" filter, every week on Sun, 2:00 AM - 4:00 AM. Runs indefinitely.

Manage maintenance windows

The Maintenance Windows tab lists every window on the account with its Status, Next run, Target type, Target, Recurrence type, Recurrence, Timezone and End. Search for a window by name, or use Manage Columns to show or hide columns.

Each window shows one of these statuses:

  • Scheduled: the window is waiting for its next run, shown in Next run.
  • Running: the window is active now, and alerts are paused for its target.
  • Ended: a one-shot window that has finished, or a recurring window that has passed its end date.
  • Disabled: the window has been disabled and won’t run until you enable it again.

To change a window, click it to open its details. The top of the panel shows its status and next run. Make your changes and click Save Window.

Click the … menu at the top of the panel, or at the end of the window’s row in the list, to:

  • Clone: create a copy of the window to use as a starting point for a new one.
  • Disable: stop the window from running without deleting it.
  • Delete: remove the window permanently.
Maintenance Window panel with the ... menu open, showing Clone, Disable and Delete

Related articles